UVA Lamp Skin Analyzer

UVA Lamp Skin Analyzer

Rechargeable USB
Sale price  $60.00 Regular price $80.00
Skip to product information
UVA Lamp Skin Analyzer

UVA Lamp Skin Analyzer MediSpa Aesthetica Shop

Sale price  $60.00 Regular price $80.00
ColorRechargeable USB

A portable Wood's lamp skin analyzer is a handheld ultraviolet diagnostic tool used in salons and at home to reveal hidden skin conditions—such as dehydration, oiliness, acne, and pigmentation disorders—through fluorescent color reactions.

Visible Lens Diameter: D60mm±1mm

Voltage: Below-50V AC (Safety Extra-Low Voltage AC, SELV AC)

Working Distance: 6cm±3cm

Key Features

  • UV Light & Magnification: Combines a safe long-wave UV (UVA/Wood's light) source with a built-in 2x to 3x magnifying lens.
  • Design: Compact, lightweight body with an observation window and a shielded hood or viewing area to block out ambient room light.
  • Power Options: Many modern versions feature built-in rechargeable lithium batteries via USB for wireless portability. [1, 2, 3, 4, 5]

Common Fluorescence Interpretations

  • Light Blue/White: Normal, healthy, and well-hydrated skin.
  • Yellow/Orange: Oily skin areas, clogged pores, or acne-prone zones.
  • Purple/Dark Violet: Dehydrated or dry skin lacking adequate moisture.
  • Brown/Dark-Brown: Pigmentation spots, sun damage, or uneven melanin distribution


    NEW Professional Dermatoscope Skin Medical Magnifier Detection Woods Lamp UVA Lamp For Vitiligo Detection

    1.1 Important tips and safety protection

    Thank you for purchasing this product. Please read the instructions carefully to ensure continuous and safe use of the instrument. You must follow the listed instructions for use. Wood's lamp uses a professional ultraviolet lamp chip for detection. This lamp chip can emit modulated long-wave ultraviolet light and can penetrate into the middle dermis of the skin. After epidermal melanin and dermal collagen absorb ultraviolet light of a certain wavelength,blue and other fluorescence can be found when observed in a glass mirror. The state of this fluorescence mainly depends on the conditions of the skin epidermis and skin dermis. If the health of the skin is different, the fluorescence produced will also change. The skin condition cannot be confirmed with the naked eye, but the Wood lamp can be used to obtain detailedconditions. Through the lens, the skin condition and problems of the exa miner can be easily identified.We are not responsible for personal or instrument damage caused by abnormal operation or operation.

    1.2 Matters need attention

    1.To prevent electric shock and reduce instrument failure,the instrument must not be immersed in water. If the instrument accidentally enters water, please stop using it immediately and hand it over to a professional for repair before use.

    2.The safety of the connecting cables should be carefuly observed before the instrument is put into use, and damaged cables and connectors should be handled in time.

    3.Do not look directly at the U-v light source for a long time. The patient must close his eyes during the facial examination. The instrument should be kept at a distance of 5-6 cm from the skin surface of the tester.

    1.4 Scope of application

    The Woods lamp isa toolthat uses LED to radiate a specific wavelength of 365nm to observe the condition of the skin, increase the operator's viewing angle, and facilitate observation of skin details.

    1.5 Contraindications

    Do not use this product in patients with excessive light sensitivity.

    Product parameter

    Product Name:Portable Woods Lamp

    Product Material:A BS+pc

    Power Output:5w

    Packing List

    Handheld host x1

    Charging Cable X1

    Instruction manual x1

    Li-ion lithium ion rechargeable battery

    Operation and Working principle

    3.1 Instructions on operation

    1.Cleaning cover and lens: when cleaning, please ensure that the detergent used will not

    damage the glass and outer shell, to ensulre the maximum luminosity output.

    2.Before use, the skin cleaner is applied to clean the oil and dirt on the skin surface, which

    can clearly observe the dermal state ofthe skin to a large extent.

    3.Hold the wood light and press the switch, the LED light source will light up,then check.

    4.when using the protable wood lamp, itis most appropriate to keep the instrument at a distance of 5 - 6 cm from the skin surface.

    5.Test through a magnifying glass in a dark room.

    Note:

    The equipment before the factorythrough a strict qualityinspection,if found in the use ofabnormal work, please contact the company in time during the warranty period.

    If you have any problems with the instrument or have any ulestions about its operation, please read this instruction manual carefully. warranty period.

    Principle of operation

    electrical source—controller- LED light source


    Maintenance and cleaning

    In order to ensure the normal operation of the instrument and extend the service life of the instrument, attention should be paid to the maintenance and cleaning of the instrument.

    4.1 Maintenance of instruments and accessories

    4.1.1 In order to ensure the normal and safe work of the instrument, a preventive inspection (including performance inspection and safety inspection) and maintenance of the instrument and its accessories shall be conducted every 6 months, to prove that the instrument can work normally and is in good working conditions, which is safe for medical personnel and patients and achieves the accuracy required for clinical use.

    4.1.2 Pay attention to the voltage fuctuation of the local power grid. If it exceeds the allowable range, it is recommended to add voltage stabilization equipment.

    4.1.3 The instrument shell should not be opened without permission, so as to avoid undue failure and affect the normal use.

    4.1.4 The accessories of the instrument should be gently put, do not fall, touch, pull, Cannot be wiped with corrosive substances !

    4.1.5 When the service life of the instruments and accessories expires, they shall be treated accordingly in accordance with the relevant regulations on the treatment of electronic product waste issued.

    4.2 Cleaning of instruments

    Warning: Turn off the power and cut the AC power before cleaning the instrument.

    4.2.1 Avoid using ethanol, amino or acetone cleaners.

    4.2.2 The shell, mirror body and light source ofthe instrument shall be protected from dust, and can be wiped with wireless soft cloth or sponge infiltrated with detergent.

    4.3 Storage

    If the instrument is not used for a long time, it should be wiped clean and put in the

    packaging box. The storage environment should be kept dry and ventilated.

    Woods lamp displays colored light to report skin condition

    Note: The fluorescence of hypopigmented or depigmented lesions such as vitiligo and pityriasis alba is easier to distinguish from normal skin color. Topical medications such as vaseline, salicylic acid, iodine tincture, keratin and even soap residues also have fluorescence, so you should pay attention to identification.